-40%
Lutron HWI-Q96 Integrator for HomeWorks and Sivoia QED Shades
$ 29.56
- Description
- Size Guide
Description
Model Number HWI-Q96: Q96 Integrator forHomeWorks
and
Sivoia QED
Input Voltage 12 V (from pin 2 of
Sivoia QED
link)
Regulatory Approvals Class 2 device
Environment Ambient operating temperature: 0 °C to 40 °C, 32 °F to 104 °F
Ambient operating humidity: 0-90% humidity, non-condensing . Indoor use only .
Low-Voltage Wire Type Two pair – one pair #18 AWG (1 .0 mm
2
), one pair #18-22 AWG (1 .0-0 .5 mm
2
) twisted shielded – Class 2 wire . Lutron wire model # GRX-CBL-346S-500 may be used . For connection to
Sivoia
QED
link, the #18 AWG wire must be used for +12 V and Common .
Note:
HWI-Q96 derives its power from the
Sivoia QED
link .
Low-Voltage Wiring Configuration
Between processor and Q96: Daisy-chain only . Termination required if total cable length exceeds 50 feet (15 m) . Total length of wire on any link can not exceed 1000 feet (305 m) . Maximum of four Q96 integrators and H48 dimmer interfaces per processor link configured for H48/Q96 .
Between Q96 and
Sivoia QED
commuication link: Daisy-chain or home run . Termination not required . Maximum of 96
Sivoia QEDs
per link . Total wire run distance for the entire
Sivoia QED
system can not exceed 4000 feet (1220 m) .
Low-Voltage Connections Between processor and Q96: One 4-pin removable terminal block . Terminal block will accept up to two #18 AWG (1 .0 mm
2
) wires .
Between Q96 and
Sivoia QED
: One 4-pin removable terminal block . Terminal block will accept up to two #18 AWG (1 .0 mm
2
) wires .
Addressing Via DIP switch . Set DIP switches 5-6 to give the Q96 a unique address from 1 to 4 .
DIP switches 1-4 should always be in the down position . Counts as one address on the H48/
Q96 link .
See Fig. 3, pg. 137.
Diagnostics
Between processor and Q96: The
HomeWorks
“heartbeat” LED will be flashing to indicate communication with the processor . If the LED is off, check the connections .
Between the Q96 and
Sivoia QED
: The
Sivoia QED
TX and RX communication LEDs are normally off . After limits have been set for each QED, Use the ‘All Open’ or ‘All Closed’ button and check the
Sivoia QED
communications LEDs (TX and RX) for flashing after the button
is pressed .
ESD Protection Meets or exceeds IEC 61000-4-2 standard .
Surge Protection Meets or exceeds ANSI/IEEE standard c62 .41
Dimensions
See Fig. 1, pg. 137.
Mounting Mounts in the following enclosures: HWI-LV32-120, , HWI-LV24-120, HWI-LV17-120, and HWI-ENC-CC
Shipping Weight 1 .3 lbs . (0 .59 kg)